Guide · Updated 15 November 2026
Checking camping gas and equipment: a Quartermaster's guide
Camping gas can cause fire, explosions and carbon monoxide poisoning, and the checks that prevent them are simple: look at the hoses, the regulators and the stoves before every use, replace hoses at five years, store and carry cylinders upright, and bring a carbon monoxide alarm. The rest of the stores need checking too, in good time before each trip.
This guide is for Quartermasters and leaders who look after a Group’s kit. It summarises Scouts’ safety guidance and HSE’s advice. It isn’t a substitute for the manufacturer’s instructions or a Gas Safe engineer.
What to check, and when
| Kit | Check | Notes |
|---|---|---|
| Gas hoses | Start of season, and before each use | Replace at 5 years from manufacture, or sooner if damaged |
| Regulators | Before each use | Marked BS EN 16129, right gas and pressure for the appliance |
| Portable gas stoves | Before every event | Not serviceable: replace when worn or damaged |
| Fixed gas appliances (hall kitchen, catering trailer) | Every year | Serviced by a Gas Safe registered engineer |
| Carbon monoxide alarms | Test as the maker says | Replace at 10 years from going into service |
| Meths, petrol and multi-fuel stoves | Before every event | Serviced as the maker says, by someone competent |
| Tents, ropes, canoes and other large kit | 6 weeks before a trip | Time to repair or replace |
| Pots, axes, saws, lamps and other small kit | 2 weeks before a trip | Clean and safe |
| Electrical items | Visual check before use | Formal testing as often as the risk needs |
The person checking must be competent: someone who knows the equipment and what a fault looks like. If there’s any doubt about an item, don’t use it until someone competent has looked at it.
Gas hoses and regulators
Scouts’ guidance asks a competent person to check hoses at the start of the camping season, and again just before setting up. Look for:
- cuts, scuffs, cracks, or a hose that’s stretched, flattened or kinked;
- stiffness, cracking, a peeling outer layer, or softening from oil;
- blisters, soft spots, corrosion or loose fittings;
- missing or worn sealing washers, and damaged connectors.
And the rules for what you fit:
- Hoses last five years from manufacture. Replace them sooner if damaged, and record the date each one is fitted.
- The right hose: rubber hoses marked BS EN 16436-1 or -2. A low-pressure hose is only for regulated pressures up to 50 mbar. Keep hoses short, clipped on properly, and away from hot surfaces.
- The right regulator: marked BS EN 16129 (older ones may say BS EN 12864 or BS 3016), for the right gas and the appliance’s pressure. Don’t mix propane and butane parts.
- Fitting it: the thread is left-handed. Check the parts are clean and, on butane, that the washer is there. Only a competent person connects or disconnects cylinders and regulators.
Stoves and cartridges
- Before every event, check each stove: suitable for the job, labels and instructions readable, no damage, corrosion or wear, connections secure, fuel containers sound.
- Portable gas stoves can’t usually be serviced. Replace them when worn or damaged, and never modify one.
- Fixed appliances in the hall, a catering trailer or a marquee are serviced every year by a Gas Safe registered engineer. Sooty flames mean stop and get it serviced.
- Retire pierceable cartridges. They can’t be taken off once fitted. Scouts recommends self-sealing screw-on cartridges instead. Old inherited kit is where they turn up.
- Store stoves and lamps empty, with leftover fuel in a proper container, labelled as flammable.
Storing and carrying cylinders
- Store gas somewhere secure and well ventilated, ideally a gas cage outside. A few small cartridges can be kept indoors, near the floor, away from anything that could light them. Ask your building insurer whether they have rules too.
- Never below ground level. LPG is heavier than air and pools in low places.
- Carry cylinders upright and secured, with the transport in your risk assessment. Avoid carrying people and cylinders together; if you must, ventilate the vehicle. Carry a suitable extinguisher and show a flammable gas sign.
- At camp, cylinders stand upright, outside the cooking tent, where the valve can be reached in a fire: not under the cooking table.
Carbon monoxide alarms
Scouts asks for an audible CO alarm that meets British Standards wherever gas is used. For camping and other temporary settings, that’s a portable alarm to BS EN 50291-2. Buildings such as your hall use BS EN 50291-1. Alarms last ten years: write the date it went into service on it. Test as the maker says, and brief everyone on what to do if it sounds.
If you smell gas
- Put out naked flames and close the cylinder valves. Stop using every appliance.
- Get everyone out of the area, and only tackle the leak if you’re confident to.
- Never look for a leak with a flame: trace it by smell, and confirm it with leak-detecting fluid on the joint.
- Call the National Gas Emergency Service on 0800 111 999.
- Don’t use that equipment again until it’s been repaired.
Tools, ropes and the rest
- Six weeks ahead for big kit, two weeks for small. Scouts suggests tents, ropes and canoes at least six weeks before a trip, and pots, axes, buckets, utensils and lamps at least two weeks before.
- Axe and mallet shafts: check they’re sound and safe. Store edged tools dry and locked away.
- Ropes: dry them before storing, preferably hung up, and inspect them for wear.
- Life-safety and specialist kit, such as buoyancy aids or climbing equipment: get someone experienced to check it.
- Borrowed or hired kit: check it before you take it, and write down and photograph any damage.
- Cool boxes: washed, dried and stored with the lids off.
For tents in detail, see looking after Scout tents.
Electrical kit and PAT testing
The law says electrical equipment that could cause injury must be kept safe. HSE says it doesn’t make yearly PAT testing a legal requirement: how often to test depends on the equipment and how it’s used.
- Look before you plug in: anything damaged means don’t use it. A sensible volunteer with enough knowledge can do visual checks.
- Test what gets moved and used a lot, such as urns, kettles, extension leads and kit that goes to camp. Combined inspection and testing needs someone with the right knowledge and equipment.
- New equipment needs a visual check, not a formal test.
- Your hall’s insurer or landlord may ask for testing on a schedule. Follow what they ask.
Keeping records
Scouts’ guidance asks you to keep a record of servicing, tests and inspections, and of when parts such as hoses were fitted. HSE says records aren’t legally required for electrical testing, but they’re a good way to show your checks happen. Either way, a list that says what you own, when it was last checked and when it’s next due is what makes the checks happen at all.
Let the due dates come to you
- Quartermaster records when each item was last inspected and when it’s next due, and emails your leaders when it is. Say how often it’s checked, such as every year, and the next due date moves on by itself after each inspection or stock take. Inspection-due reminders.
- For electrical kit it keeps the PAT certificate number and result, and a failed test shows a red badge. For a gas hose or a CO alarm, put the fitted date in its notes and set it to repeat every five or ten years.
- Report an issue records a fault with a photo and can mark the item as needing repair, and a stock take checks the whole store.
Free for your first 15 items. Tools for Scouting is made by a Scout volunteer and isn’t part of The Scout Association.
Sources
- Scouts, Gas safety: Liquified Petroleum Gas (published September 2026).
- Scouts, Using stoves safely (published September 2026).
- Scouts, Packing tips, kit guidance and looking after equipment.
- HSE, PAT: portable appliance testing FAQs.
- All read on 15 November 2026.
More guides
- PAT testing for Scout groups: what the rules really sayQuartermasters, premises teams and Trustee Boards
- Campfire skits and run-ons for ScoutsLeaders, Young Leaders and patrols planning a campfire
- How to run a Scout campfire: the fire, the programme and staying safeLeaders running a campfire at camp or a meeting
- Looking after Scout tents: drying, storing and repairsQuartermasters and anyone who looks after a Group's tents