PAT testing for Scout groups: what the rules really say
The hall kettle, the urn, the projector, the camp fridge, the extension reels in the stores: a Scout group owns more electrical kit than most people realise. It all has to be kept safe, but that doesnât mean a sticker on every plug every year.
The law asks for electrical equipment to be maintained so it isnât dangerous, and leaves how to you. Scoutsâ guidance, updated in November 2026, now calls portable appliance testing Electrical Equipment Testing (EET) and asks every group to take a risk-based approach.
This guide is a summary of HSEâs and Scoutsâ guidance, not legal advice. Anything to do with your hallâs wiring is a job for a qualified electrician.
Is PAT testing a legal requirement?
No. HSE is clear that the Electricity at Work Regulations 1989 require electrical equipment that could cause injury to be maintained in a safe condition, but donât say what has to be done, by whom or how often. Thereâs no legal requirement to test every year, to label equipment, or to keep records.
That doesnât mean doing nothing. Scouts asks every group to manage electrical safety on its premises and at events, and to decide what each item needs from how and where itâs used. Your insurer or your landlord may also ask for evidence, so check what they expect.
The three levels of check
Scoutsâ guidance uses all three, in proportion to the risk:
| Check | How often | Who does it |
|---|---|---|
| User check | Every time, before use | Anyone using it |
| Formal visual inspection | Risk-based, often once a year | A competent person |
| Combined inspection and test (the old PAT) | Risk-based, every 1 to 5 years | Someone trained and competent in testing |
Scouts says user checks and formal visual inspections are often the most effective way of reducing electrical risk, with testing used where the risk warrants it. HSE agrees: most faults can be found just by looking, and some canât be found by testing at all.
EET also covers equipment built into the hall, such as heaters, hand dryers and air conditioning, not only things with a plug.
How often?
Thereâs no single interval. Scouts suggests weighing four things, and checking more often the higher the risk:
- The equipment: a kettle in daily use in a busy kitchen is higher risk than a projector used now and then in a dry room.
- Where itâs used: outdoors, in a camp kitchen or washroom, or somewhere dusty or dirty means more checks.
- Who uses it: young people, or volunteers with little electrical knowledge.
- Its history: older items, and anything that has gone wrong before.
HSE suggests these starting intervals for lower-risk places, to be adjusted if faults turn up:
| Equipment | User checks | Formal visual inspection | Inspection and test |
|---|---|---|---|
| Earthed (Class I) equipment, eg electric kettles | Yes | 6 months to 1 year | 1 to 2 years |
| Hand-held double-insulated (Class II), eg some kitchen equipment, irons | Yes | 6 months to 1 year | No |
| Double-insulated, not hand-held, eg fans, table lamps | No | 2 to 3 years | No |
| Office IT, eg desktop computers, photocopiers | No | 1 to 2 years | None if double-insulated, otherwise up to 5 years |
| Cables and plugs, extension leads | Yes | 1 year | 2 years |
| Equipment used by the public, eg in hotels | By a member of staff | 3 months | 1 year |
A Scout hallâs urn and kettle are Class I, the storesâ extension reels are cables and plugs, and kit that hirers and visitors use is closest to âequipment used by the publicâ. Kit that goes to camp lives a harder life than anything in an office, so itâs sensible to check it before every trip.
The user check
This is the one everybody can do, every time. Switch off and unplug first, then look for, as HSE lists them:
- a damaged plug, or a cable that isnât held firmly with no inner wires showing;
- a damaged cable, or one repaired with tape or an unsuitable connector;
- a cracked or damaged casing;
- burn marks or staining that suggest overheating;
- bent plug pins, water or dirt, which Scouts adds.
If anything looks wrong, donât use it: take it out of use, label it, and tell whoever looks after the kit. Make the check part of how your leaders and Young Leaders handle kit, and put trailing cables where nobody trips on them.
Who can do it?
HSE says you donât need an electrician for visual inspections in a low-risk setting: a sensible person with enough knowledge and training can do them. Testing needs more: the right test equipment, the ability to use it properly, and the knowledge to understand the results. Many groups have a parent or leader whoâs trained to test, or pay a local tester to do the lot in one visit.
New equipment should arrive safe, so HSE says it doesnât need a formal test, just a visual check that it isnât damaged.
Labels and records
The law doesnât require them, but HSE says a record or a label is a useful way to show a scheme exists and to see whether itâs working. Scouts asks groups to label or tag tested equipment with the date and the outcome, so everyone can see whatâs been checked, and says anything that fails or looks unsafe must be removed from use or physically isolated.
A simple list does the job: each item, where it lives, its last check and result, and when the next one is due. It also tells you what you own when you come to insure it.
Donated kit, camp and events
- Donated or second-hand electrical items: Scouts says decline them, or have them tested by a competent person before theyâre used.
- Volunteersâ and visitorsâ own kit: Scouts includes personal devices used on your premises in the approach. Laptops, phones, chargers and handheld radios are generally safe and need no special precautions.
- Outdoors and at camp: HSE suggests a residual current device (RCD) between the supply and the equipment, tripping at no more than 30 mA. Test a plug-in RCD with its button before use.
- Big events with staging, lighting, sound or catering may need a temporary installation designed and certified by an electrical contractor. For a smaller event using existing sockets, extension leads and a portable generator, Scouts says the principles still apply: RCD protection, tidy cables and a competent person keeping an eye on it.
The hallâs wiring
The fixed wiring is separate from EET. Scouts says it should be inspected and tested by a qualified electrician, who gives you an Electrical Installation Condition Report (EICR) stating when the next one is due: typically at least every five years for premises used regularly by young people, and more often for overnight stays or ageing installations. Fix anything coded C1 or C2 promptly, test the RCD in the consumer unit with its button, and keep the circuits labelled. If you rent your hall, the owner is usually responsible.
A checklist for your group
- List every piece of electrical kit you own, in the hall, the stores and the camp boxes.
- Decide, item by item, how often it needs a formal visual inspection and whether it needs testing.
- Teach leaders and Young Leaders the user check, and make it a habit.
- Book a competent tester for the items that need it, and label each with the date and result.
- Take anything that fails out of use straight away, and decline untested donated kit.
- Check the hallâs EICR date, and use RCDs outdoors and at camp.
Keeping the list
Quartermaster keeps your groupâs kit list, with where each item lives and its condition. For electrical kit, record the PAT result and certificate number, when it was last inspected and when itâs next due, and how many months between checks. It emails your team when an inspection falls due, shows a failed item in red, and you can scan an itemâs QR code in the stores to open its record.
Tools for Scouting is made by a Scout volunteer and isnât part of The Scout Association or HSE.
Sources
- Scouts, Electrical safety (FS120220), published November 2026, and Other safety management considerations.
- HSE, PAT: portable appliance testing FAQs and Work using electrically powered equipment.
- All read on 17 November 2026.
More guides
- Checking camping gas and equipment: a Quartermaster's guideQuartermasters and leaders who look after a Group's kit
- Looking after Scout tents: drying, storing and repairsQuartermasters and anyone who looks after a Group's tents
- A Scout camp kit listYoung people, parents and leaders
- Scout hall safety checks: what to check, and how oftenPremises teams, Trustee Boards and anyone who looks after a Scout hall